Patient Monitor12 inch

NO.:001125
Product Model:YK-8000C
File Download

Category:

Application Range

  • Adult/Pediatric/Neonatal/Medicine/Surgery/Operating Room/ICU/CCU

Display

  • 12.1”real color TFT screen

Environment

  • Operating environment:
    Temperature::0~40℃
    Humidity:15%~80%
    Pressure:86.0kPa~106.0kPa
    Transport and Storage environment:
    Temperature:-20~50℃
    Humidity:10%~90%
    Pressure:86.0kPa~106.0kPa

Power Requirements

  • AC:100~240V,50Hz/60Hz
  • DC:Built-in rechargeable battery
  • Battery:11.1V 240wh Li-ion battery.2h operating after full charge.5min operating after low battery alarm

Date Storage

  • Trend diagram/table:720h
  • NIBP review:10000 events
  • Wave review:12h
  • Alarm review:200 alarm events
  • Support drug concentration titration analysis

ECG

  • 5 lead:RA,LA,LL,RL,V
  • Lead mode:Ⅰ,Ⅱ,Ⅲ,AVR,AVL,AVF,V
  • Gain:*1.25mm/mV,2.5mm/mV,5.0mm/mV,10mm/mV,20mm/mV(error≤5%)
  • Sweep speed:6.25mm/s,12.5mm/s,25mm/s,50mm/s(error≤±10%)
  • Bandwidth:surgery1~25Hz
  • Monitor:0.5~40Hz
  • Diagnostic 0.05~130Hz
  • Sensitivity:>200μVP-P
  • CMRR:≥112dB
  • Differential Input Impedace:>5M
  • ohm Electrode Offset Potential:±300mV
  • Polarization Voltage:≥5M
  • Calibration Voltage:1mV±5%

ST Segment

  • St Segment Range:-2.0mV~﹢2.0mV
  • Accuracy:0.02mV

NIBP

  • Method:Oscillometry
  • Measure mode:Manual,Auto,STAT
  • Measure interval in auto mode:1~5/10/15/30/60/90/120/180/240/480min
  • Measure period in STAT mode:5min
  • Pulse rate range:40~240bpm
  • Measure&alarm range:Adult
  1. SYS       40~280mmHg
  2. DIA        10~220mmHg
  3. MEAN    20~240mmHg

Pediatric

  1. SYS       40~220mmHg
  2. DIA        10~160mmHg
  3. MEAN    20~170mmHg

Neonatal

  1. SYS       40~135mmHg
  2. DIA        10~100mmHg
  3. MEAN    20~110mmHg
  4. Static pressure measurement
  5. Range:0~300mmHg
  6. Accuracy:±3mmHg
  7. Resolution:1mmHg accuracy:Max.Mean Error:±5mmHg,Max.Standard Deviation:8mmHg
  8. Overpressure protection:Adult 300mmHg,Pediatric 240mmHg,Neonatal 150mmHg

SpO2

  • Measurement range:0~100%
  • Resolution:1%
  • Accruacy:70~100%±2%,40%~69%±3%

Pulse Rate

  • Measure/alarm range:20~300bpm
  • Resolution:1bpm
  • Accuracy:±3bpm

RESP

  • Method:impedance between RA-LL
  • Resp impedance range:0.3~3Ω
  • Base impedance range:200Ω~4000Ω
  • Bandwidth:0.3~2.5Hz
  • Gain:*0.25,*0.5,*1,*2,*4
  • Resp rate:
  • Measurement Range
  • Adult  0~120BrPM
  • Neonatal/Pediatric 0~150BrPM
  • Resolution 1BrPM
  • Accuracy:7~150BrPM(±2BrPM),0~6Brpm(unspecified)
  • Apnea Alarm:10~40s

TEMP

  • Channel   2
  • Measure & alarm range:0~50℃
  • Resolution:0.1℃
  • Accuracy(no sensor):±0.1℃(0~50℃)

Standard accessories

  • NIBP cuff & tube
  • ECG cable & electrodes
  • SpO2 sensor
  • TEMP probe
  • Lithium-ion battery
  • Power cable
  • Operator’s manual

Optional accessories

  • IBP
  • CO2
  • Nellcor SpO2